Disclosure: This page contains affiliate links. If you buy through a link on this page, we may earn a commission at no additional cost to you. As an Amazon Associate I earn from qualifying purchases.
Researched from manufacturers' published figures and this site's sizing method — not hands-on tested. Drafted with AI assistance and editorially reviewed. This page prints no prices; the buttons show the live ones.
The honest answer is a number you can compute, and it is almost never the number on the box you were about to buy. Power stations are sold by their biggest figure — watt-hours of capacity — and bought against a vaguer question: will it run my stuff through an outage? This page turns that question into arithmetic. Measure or estimate your loads, decide how many hours they must run, and the calculator below returns the capacity you actually need — with every assumption visible, so you can argue with it.
The framing here is an Illinois winter outage, because that is the outage that sizes hardest: the power fails in January, the house is cooling, and the loads that matter are the refrigerator, the furnace blower that moves your heat, and — in many houses — a medical device that does not get to take the night off. Summer sizing is the same maths with kinder numbers.
Daily energy = Σ (watts × hours × duty cycle). Each load contributes its draw multiplied by how long it runs. Loads with motors and compressors — refrigerators, furnace blowers — do not run continuously; they cycle. The duty cycle is the honest fraction: a fridge that runs 40% of the time at 150 W consumes what a 60 W continuous load would. Skipping the duty cycle is how sizing goes wrong in the expensive direction; inventing a tiny one is how it goes wrong in the dangerous one.
Nameplate capacity = daily energy ÷ usable fraction × (1 + reserve). A station cannot spend its whole nameplate: inverter losses and the battery's usable depth mean roughly 85% of the printed watt-hours are yours to spend — the calculator uses 0.85, shown, and you can change it. It then adds a 20% reserve by default, because an outage plan that ends at 0% battery at hour eleven of a twelve-hour night is not a plan.
The inverter check is separate. Capacity is energy; the inverter is power. Motor loads surge at startup — a fridge that runs at 150 W can demand several times that for a second when its compressor starts. The station's surge rating must clear your largest motor's surge plus everything else running at that moment, or the station trips with capacity to spare. The calculator checks both numbers and tells you which one sized your station.
Outage duration to cover: hours (the worksheet's hours are per 24; they scale to this duration). Usable fraction: · Reserve: · Solar panels: W × effective sun hours (a deliberately conservative December assumption — replace it with your own measurement).
| Load | Watts | Hours / 24 | Duty % | Motor? | Energy |
|---|
Sizing 1 — The night the heat matters (12 hours). Furnace blower 600 W at a 50% duty cycle through a cold night: 600 × 12 × 0.5 = 3,600 Wh. Refrigerator 150 W at 40%: 150 × 12 × 0.4 = 720 Wh. A CPAP at 50 W for 8 hours: 400 Wh. Router, one LED lamp, two phones: ≈ 200 Wh. Total ≈ 4,920 Wh — ÷ 0.85 × 1.2 ≈ 6,950 Wh of nameplate. The lesson is the point of this page: adding the furnace blower to a winter night moves you out of the single-portable-station class entirely. Better to learn that from arithmetic than from a cold house.
Sizing 2 — Fridge, CPAP, and comms (12 hours, no blower). The same night minus the furnace: 720 + 400 + 200 = 1,320 Wh → ÷ 0.85 × 1.2 ≈ 1,860 Wh nameplate — the large-portable class, and a realistic one.
Sizing 3 — The space heater reality check. A resistive space heater draws about 1,500 W, continuously, no duty cycle to save you: one hour of space heat ≈ 1,500 Wh — more than Sizing 2's entire night. Electric resistance heat and portable batteries do not mix. Heat the person (an electric blanket at ~75 W) or heat with fuel; do not size a battery around a space heater.
A panel's rating is its output in ideal laboratory sun. An Illinois December gives you short days, a low sun, and the possibility of snow cover — the calculator therefore treats solar as an input you set, with a deliberately conservative worked assumption (an hour-equivalent of full output across a December day in the placeholder), stated so you can replace it with your own measurement. Solar on this page is a range extender, never the plan — and a panel under snow produces a rounding error, which the plan should assume on the day it matters most.
Every wattage above is a labelled assumption. Your refrigerator's actual draw, your blower's actual plate rating, your CPAP's actual consumption are knowable numbers — this library's measuring guide walks through getting them with a plug-in meter, and the running-cost guide runs the same machines through the cost side. Ten minutes of measuring replaces every assumption in the calculator with your household's facts.
Capacity decides how long the station runs; recharge decides whether it is ready for the second night. A winter storm outage is often a sequence — power back for six hours, gone again for ten — and a station that needs fourteen hours on a wall outlet to refill is a one-night answer wearing a two-night price. When you compare stations against your computed number, read the recharge specification with the same care as the capacity, and size for the outage pattern, not the outage moment.
With a nameplate target and an inverter requirement, the category narrows itself: the portable lines from EcoFlow, Jackery, and Bluetti each publish capacity, continuous and surge output, and expansion options — compare your two computed numbers against their specification sheets, in that order, and let products that miss either number eliminate themselves. Buy for the sizing you computed, not the sizing a sale is pushing. Buttons below are plain retailer links; no button on this page earns us anything today, and the sizing does not change when one does.
Check price at EcoFlow · Check price at Jackery · Check price at Bluetti
Related in this library: the electricity cost calculator, the space heater cost page, and the standby power guide.